Calibration Shaft Variation

Dave Tutelman -- 3/9/2006


As people have been building their NeuFinders, they have been posting the profile of their calibration shaft, as measured on their NF4. It turns out this can be a good sanity test, and has helped in finding and fixing bugs in a couple of machines. So let me show you a sample of six calibration shaft profiles. Note that all are from the same batch of Mercury Savage shafts at 300cpm. Other batches may vary from this data, though we haven't seen much variation so far. Other models of shaft will undoubtedly give more variation from this data; this is significant because Mercury is going out of business, and we will have to pick a new model for our calibration shaft.

Here is the data:

Statistic
Nominal
Load
39"
34"
29"
24"
19"
Stats
Median
4.535
2.37
2.84
3.555
4.745
7.175
Mean (average)
4.532
2.39
2.85
3.56
4.755
7.207
Standard deviation
15g
30g
24g
24g
40g
83g
Range
(and width of range)
4.51-4.55
(40g)
2.36-2.44
(80g)
2.83-2.89
(60g)
3.52-3.57
(50g)
4.71-4.83
(120g)
7.15-7.37
(220g)
Shaft
Identification
Nominal
Load
39"
34"
29"
24"
19"
Raw
Data

NF4-0  F
4.51
2.37
2.83
3.52
4.71
7.15
NF4-0  I
4.52
2.36
2.85
3.56
4.83
7.37
NF4-0  H
4.53
2.40
2.83
3.57
4.76
7.19
NF4-0  A
4.54
2.37
2.83
3.57
4.74
7.16
NF4-0  E
4.54
2.40
2.86
3.59
4.75
7.21
NF4-0  J
4.55
2.44
2.89
3.55
4.74
7.16
 
How to use the data:
  1. This is mostly intended as a sanity test of the construction of your NF4. So you are looking to see if your NF4 is measuring your calibration shaft in a way consistent with other calibration shafts. The data above is useful for that purpose if the raw calibration shaft is a Mercury Savage steel shaft with a raw frequency of 300-302cpm. If not, don't try to use this data as a sanity test. It is likely not to match your shaft, even if your NF4 is well-built and properly adjusted.
  2. Profile your own calibration shaft, and look at the profile.
    • If each station is close to the median number in the table above, then your NF4 is probably spot-on.
    • If each station is somewhere within the range of the table above, you have nothing to worry about.
  3. If your numbers are outside this range:
    1. Review the critical dimensions of your NF4, to be sure it was cut properly.
    2. Be sure everthing that needs to be secure and tight is so. That especially includes the bolts supporting the bearing blocks and rotator board pivot bearings. Be sure the "kerf-squeezing" bolt is as tight as possible.
    3. Go through the entire calibration procedure again, just to be sure you did it right.
    4. Repeat the profile of the calibration shaft, and compare the numbers again to the table above. If they haven't changed from the first time....
    5. Consult the NF4 discussion group for help.